Performance characteristics:
1. Convenient installation: easy installation and demolition, small footprint, and can be installed indoors / outdoors.
2. Efficient and environmental protection: only a small amount of power is needed, and the energy consumption is only 1 / 3-1 / 4 of electric heating; compared with coal, oil, and gas water heaters, it can save about 75% of operating costs.
3. Environmental protection and no pollution: without any burning matter and emissions, it is a sustainable and environmentally friendly product.
4. Reliable and safe operation: The entire system operates as a flammable, explosive, poisoning and other hazards in traditional dryers. It is a safe and reliable semi-closed drying system.
5. Long service life and low maintenance cost: mature process technology, reliable and stable performance, long service life; safe and reliable operation, fully automatic and manual operation, intelligent control.
6, comfortable and convenient, high degree of automation and intelligence: self-controlled constant temperature device, continuous drying operation for 24 hours.
7, can be widely used in food, chemical, pharmaceutical, paper, wood, agricultural and sideline processing industries such as heating and drying operations.

model

KFXRS-7HYII

KFXRS-13HYII

KFXRS-15HYII

KFXRS-26HYII

KFXRS-30HYII

Power supply form

V/HZ

3803N~50HZ

Rated heating capacity

KW

7

13

15

26

30

Dehydration rate

/

7

13

15

26

30

Rated temperature

70

70

70

70

70

Maximum temperature

80

80

80

80

80

input power

KW

2.75

4.8

6.2

9.3

11.8

Outside fan

power

KW

0.25

0.6

0.6

1.2

1.2

Air volume

m3/h

4600

8400

8400

16800

16800

Inner fan

power

KW

0.55

1.1

1.1

2.2

2.2

Air volume

m3/h

5870

8513

8513

17026

17026

Refrigerant

/

High cold refrigerant

Compressor form

/

Scroll compressor

Throttling device

/

Thermal expansion valve

noise

dB(A)

≤50

≤58

≤68

≤62

≤62

Dimensions(L×W×H)

mm

693×1965×1150

1257×1992×1073

1257×1992×1073

1257×1992×1588

1257×1992×1588

Unit weight

kg

120

280

285

310

360

Application Environment
range

5~43


Remarks:
1. Test conditions: dry bulb temperature 20 ℃, wet bulb temperature 15 ℃, initial water temperature 15 ℃, termination water temperature 55 ℃;
2. Models, parameters, and performance may change due to product improvements. Specific parameters please refer to the product nameplate.